Must Flow Path
From Navigates Help
| Physical |
|---|
| Location Meter Location Group Section Unsubscribed Firm Capacity Notices Must Flow Path Inter-Asset Location |
The Must Flow Path screen allows users to create a path of gas flow that passes through a certain point. The components that make up a path are:
- From Point - The beginning of the path. It can be one or several points, a section or a zone.
- To Point - The end of the path. It can be one or several points, a section or a zone.
- Must Flow Through Point - One or several points through which the gas must flow when it travels from locations specified in the From matrix to the locations specified in the To matrix.
A path must have the endpoints and the pass-through points. For example, if every time gas flows from any point in zone A to any point in section B, it has to pass through point C, the path will have Zone A in the From matrix, Section B in the To matrix and Point C in the Must Flow Through matrix.
Contents |
[edit] View Paths
Click
to retrieve paths.
Select a record from the list to view details.
[edit] Create Paths
To create a new path of flow:
To specify the physical aspect of the path:
- Click the [New] button at the top of the From matrix.
- Specify a point, zone or section and effective begin and end dates.
- Click the [New] button at the top of the To matrix.
- Specify a point, zone or section and effective begin and end dates.
- Click the [New] button at the top of the Must Flow Through Points matrix.
- Specify a point, zone or section and effective begin and end dates.
- Click
.
[edit] Delete Points
To delete points from the Must Flow Path:
- Select the point you wish to delete.
- Click the [Detele] button aat the top of the corresponding matrix.
- A verification widow will pop up asking is you wish to continue. Click [YES].
- Click
.
| NOTE: You may delete only those points, whose association with the path has not become active yet; i.e., the effective begin date has not passed yet. |
[edit] Deactivate Points
To deactivate points in the Must Flow Path:
[edit] FIELDS
- Point / Zone / Section - Physical aspects of the path.
- Updater - ID of the user or process that performed the last update.
- Update TimeStamp - Timestamp of last update.
- Must Flow Point - Point through which the flow must pass.
- Service - Type of service to which the must flow path applies.
- Eff Begin/End Date - Effective date range.